Static var generators (SVG), also known as active power factor compensators (APFC) or instantaneous stepless reactive power compensators, are the ultimate answer to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications. They are a high performance, compact, flexible, modular and cost- effective type of active power filters (APF) that provide an instantaneous and effective response to power quality problems in low or high voltage electric power systems. They enable longer equipment lifetime, higher process reliability,improved power system capacity and stability, and reduced energy losses, complying with most demanding power quality standards and grid codes.

Key words:

AC charging pile, DC charging pile, charging accessories

Classification:

Product Consulting:

Product Description

Static var generators (SVG), also known as active power factor compensators (APFC) or instantaneous stepless reactive power compensators, are the ultimate answer to power quality problems caused by low power factor and reactive power demand for a wide range of segments and applications. They are a high performance, compact, flexible, modular and cost- effective type of active power filters (APF) that provide an instantaneous and effective response to power quality problems in low or high voltage electric power systems. They enable longer equipment lifetime, higher process reliability,improved power system capacity and stability, and reduced energy losses, complying with most demanding power quality standards and grid codes.

Low power factor increases the active energy losses of installations and affects their stability. It is typically caused by inductive or capacitive loads that demand extra reactive power to perform proper ly. Other contributors to low power factor are harmonic currents produced by nonlinear loads and the change of load in the electric power system.

SVG Working Principle

 

The principle of the SVG is very similar to that of Active Power Filter, When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. YIY-SVG is also capable of correcting load imbalance.

1

SVG Technical Specifications

 

TYPE Series 220V Series 400V Series 500V Series 690V
Max neutral w ire current 5KVar 10KVar15KVar/ 35KVar/50KVar/ 75KVar/100KVar 90KVar 120KVar
Nominal voltage AC220V(-20%~+20%) AC380V(-20%~+20%) AC500V(-20%~+20%) AC690V(-20%~+20%)
Rated frequency 50Hz±5%
Network Single phase Three-phase three-wire/three-phase four-wire
Response time <10ms
Reactive power compensation rate >95%
Machine efficiency >97%
Switching frequency 32kHz 16kHz 12.8kHz 12.8kHz
Feature selection Deal with harmonics/Deal with harmonics and reactive power Deal with harmonics/Deal with harmonics and reactive power/ Deal with harmonics and three-phase unbalance /Three options
Numbers in parallel  No limitation. A single centralized monitoring module can be equipped with up to 8 power modules
Communication methods Two-channel RS485 communication interface (support GPRS/WIFIwireless communication)
Altitude w ithout derating <2000m
Temperature -20~+50°C
Humidity  
Pollution level Below level Ⅲ
Protection function Overload protection, hardware over-current protection, over-voltage protection, power grid voltage imbalance protection, power
failure protection, over-temperature protection, frequency anomaly protection, short circuit protection, etc
Noise <50dB <60dB <65dB
Installation Rack/wall hanging Rack
Into the way of line Back entry (rack type), top entry (wall-mounted) Top entry
Protection grade  IP20

1 

SVG Product Appearance

 

1

Model Range

 

Model Compensation capacity(kvar) System voltage(V) Size(D1*W1*H1)(mm)

Cooling mode

SVG-5-0.22-2L-R 5 220 396×260×160

Forced air cooling

SVG-35-0.4-4L-R(Compact)

35

400

515×510×89

Forced air cooling

SVG-50-0.4-4L-R

50

400

546×550× 190

Forced air cooling

SVG-75-0.4-4L-R

75

400

586×550×240

Forced air cooling

SVG-100-0.4-4L-R

100

400

586×550×240

Forced air cooling

SVG-90-0.5-4L-R

90

500

675×495×275

Forced air cooling

SVG-120-0.69-4L-R

120

690

735×539×275

Forced air cooling

*The table is the standard specification, if you need other sizes, please contact us for customization

1

Model Range

 

Model Compensation capacity(kvar) System voltage(V) Size(D2*W2*H2)(mm)

Cooling mode

SVG-5-0.22-2L-W 5 220 160×260×396 

Forced air cooling

SVG-35-0.4-4L-W(Compact)

35

400

89×510×515  

Forced air cooling

SVG-50-0.4-4L-W

50

400

190×513×599 

Forced air cooling

SVG-75-0.4-4L-W

75

400

240×600×597 

Forced air cooling

SVG-100-0.4-4L-W

100

400

240×600×597 

Forced air cooling

SVG-90-0.5-4L-W

90

500

275×495×675

Forced air cooling

SVG-120-0.69-4L-W

120

690

275×539×735

Forced air cooling

The table is the standard specification, if you need other sizes, please contact us for customization

1

Model Range

 

Model Compensation capacity(kvar) System voltage(V) Size(D3*W3*H3)(mm)

Cooling mode

SVG-50-0.4-4L-C 50 400 Cabinet 1/ Cabinet 2 optional

Forced air cooling

SVG-100-0.4-4L-C

100

400

Cabinet 1/ Cabinet 2 optional

Forced air cooling

SVG-200-0.4-4L-C

200

400

Cabinet 1/ Cabinet 2 optional

Forced air cooling

SVG-250-0.4-4L-C

250

400

Cabinet 1/ Cabinet 2 optional

Forced air cooling

SVG-300-04-4L-C

300

400

Cabinet 1/ Cabinet 2 optional

Forced air cooling

SVG-400-0.4-4L-C

400

400

Cabinet 1/ Cabinet 2 optional

Forced air cooling

SVG-270-0.5-4L-C

270

500

Cabinet 1

Forced air cooling

SVG-360-0.69-4L-C

360

690

Cabinet 1

Forced air cooling

*Cabinet 1 size: 800*1000*2200 mm,Can accommodate 5 modules.

*Cabinet 2 size: 800*1000*1600 mm,Can accommodate 3 modules.

*The table is the standard specification, if you need other sizes, please contact us for customization